Some precautions for installing the octagonal rod.
Category: Industry News
Mar 22,2022
Some precautions for installing the octagonal pole
Pay attention to whether the octagonal pole is vertical to the ground during installation
IfOctagonal polethe verticality does not meet standards, it may tilt or even collapse in the future, causing a lot of unnecessary trouble. So, how to correct the verticality of the octagonal pole? Let's take a look at the introduction provided by professional octagonal pole manufacturers.
1. First, let's take a look at the bottom, which is the part with wings, to see if it is straight. There is a simple method to measure whether it is vertical.
The method is to tie a weight with a thin nylon rope, hold the top of the nylon rope with your hand, at a distance ofOctagonal poleabout 10m, let gravity drop naturally. Then, when the nylon rope is 20cm away from the hanging ring, move up and down with the vertical line of the nylon rope passing through the hanging ring and the bottom of the octagonal pole.
If it can still be used in this way after intersecting north, south, east, and west, then the bottom seam's verticality is acceptable.
If you find that the bottom of the octagonal pole is seriously not parallel to the nylon rope, adjustments need to be made in time; otherwise, the section inserted above will not be vertical and may even become more slanted as it goes higher. This can be referred to as 'the lower beam is not straight, and the upper beam is crooked.'
2. Check if the insert is in place. Generally speaking, whether it is an octagonal pole, communication tower, or beautification tower, any steel column that needs to be inserted will have a theoretical insertion depth during design.
If the actual insertion depth differs greatly from the theoretical insertion depth (more than 20cm), installation may not be appropriate. Only when the depth is confirmed can effective verticality be ensured.
3. If it is confirmed that the bottom is relatively vertical and other parts are inserted but still not straight, there is only one possibility: the insertion direction is incorrect.
Since monitoring poles are mostly octagonal light poles, manufacturers of octagonal light poles will conduct a series of insert tests before finished products leave the factory.
After a series of successful debugging steps, installers need to mark certain positions onOctagonal polethe pole body to ensure correct installation by the construction team. If assembly is not done according to marked directions, even if the bottom connector is vertical and inserted properly, it may lead to incorrect assembly.
After introducing these steps, we clearly understand that if some details of installing monitoring poles are not handled carefully, there will be significant trouble in the future.
Therefore, when installing octagonal poles, manufacturers must instruct relevant installation personnel to pay attention to every detail to avoid incorrect insertion of octagonal poles.
Due to the excessive weight and height of octagonal poles, once there is a slight deviation issue, going back for secondary correction will be a huge project that wastes a lot of manpower and resources and causes considerable losses.
Alright, I won't elaborate too much today. I hope the explanations above are helpful to you. If anyone needs to purchase smart street lights or utility poles or smart road poles, feel free to contact our manufacturer.